February 16, 2022 |
The New PC-3000 Software Version is Available! |
At the ACE Lab Webinar on the Modern Challenges in Data Recovery & Digital Forensics, our technical engineers showed the features available with the PC-3000 Version 7.0.x., for example, TLER (time-limited error recovery) for WD HDD, the Data Extractor error-processing scenario, and the support of new NVMe drives based on Marvell 88SS1093 controller.
Now you can download the new version of the English, Chinese, Japanese, and Korean software:
- PC-3000 Portable II-III/Express/UDMA-E software Ver. 7.0.25
- PC-3000 SAS software Ver. 7.0.25
- Data Extractor / Data Extractor RAID Edition software Ver. 6.0.12
- PC-3000 SSD/SSD Extended software Ver. 3.0.3
The development of this version required significant reworking of the program code. In the new version, we switched to the new software development kit (SDK). The main purpose of this transition is the release of the 64-bit version. In addition, the use of a new modern development environment opens up additional opportunities for using software development technologies and allows to add new features to PC-3000 & DE more quickly and efficiently.
With the 64-bit platform, we could remove existing restrictions on the use of computer resources and speed up the work of the software.
At the moment, we continue to release the 32-bit software update. The _x64 and _x86 distributions are available for downloading and installation. We recommend installing the _x64 version on Windows 10 OS.
As usual, you will be able to get the activation either using the automatic process or manually, using one of the following European activation servers:
http://activation1.acelab.eu.com 91.233.117.43 |
http://activation2.acelab.eu.com 176.74.216.29 |
A SHORT LIST OF ENHANCEMENTS:
PC-3000 Portable, Express, UDMA
WD Marvell
ADDED | support for TLER (Time Limit Error Recovery) |
ENHANCED | SMR disk reading mode when using technological reading with program translation. CHS reading command selection (with relo & Raw) has been added |
PC-3000 Universal Utility
ADDED | calculation of HASH functions SHA1, SHA256, MD5 |
PC-3000 SAS
HGST SAS
ADDED | support for families:
|
Seagate SAS
ADDED | support for families:
Tech Mode unlock(patch+unlock) has been implemented for them. |
ADDED | ROM recording – for most families |
Data Extractor
ADDED | the support of Kuznyechik and Camellia encryption algorithms in TrueCrypt/VeraCrypt |
ADDED | the new error-processing scenario in the Data Extractor |
PC-3000 SSD
ADDED | support for B37R chips (PS3111 Controller) |
Phison SSD
ADDED | new loaders for SM2258XT and SM2259XT controllers |
PC-3000 SSD Extended
Phison SSD
ADDED | support for PS5013 PCIe NVMe controller
Supported drives: Smartbuy E13T, Apacer PP3480, Dexp L3, Novation 3D (PS5013) |
Lenovo Marvell NVMe SSD
ADDED | Lenovo Marvell NVMe and Ramaxel Marvell NVMe utilities
Ramaxel/Lenovo drives are supported:
|
A DETAILED LIST OF ENHANCEMENTS
PC-3000 Portable, Express, UDMA
WD Marvell
ADDED | support for TLER (Time Limit Error Recovery)
Setting TLER is an alternative to reading a disk with a low timeout value. However, in this case, when reading unstable LBA or BAD-LBA, a UNC error occurs, and additional issues might appear. Reading bad sectors in a classic way may cause physical drive surface damages. With the TLER function, reading BAD sectors becomes stable, fast, and safe for the drive condition. You can read more about it in this article on our blog |
ADDED | the HDD Configuration Change Mode
This mode is designed to disable disk service operations that cause SA modification in the process of subtraction, especially if there are BAD blocks |
ENHANCED | SMR disk reading mode when using technological reading with program translation. CHS reading command selection (with relo & Raw) has been added |
Universal utility PC-3000 AT
ADDED | calculation of HASH functions SHA1, SHA256, MD5 |
ENHANCED | reading test |
PC-3000 Kernel
ADDED | blocking the selection of SAS ports if the PC-3000 Express/SAS Systems of different bit (x86 + x64) sizes are installed in the system (the port selection in this case will not allow them to be used in the DE task) |
ENHANCED | major stability improvements in the PC-3000 Kernel Mode |
PC-3000 Portable III
Universal utility PC-3000 SCSI/SAS and PC-3000 USB for the PC-3000 Portable III System
ADDED | calculation of HASH functions SHA1, SHA256, MD5 in the read test and in the disk replication test |
ADDED | the ability to copy from SAS to SATA ports in the disk replication mode |
Universal Utility PC-3000 USB
CHANGED | SAT (SCSI ATA Translation) access parameters to be more compatible with USB drives that support SAT |
PC-3000 SAS
HGST SAS
ADDED | support for families:
|
Seagate SAS
ADDED | support for families:
Tech Mode unlock(patch+unlock) has been implemented for them |
ADDED | ROM recording – for most families |
ADDED | the ability to set the speed and reconnection while working with the terminal |
Data Extractor
ADDED | the "WD MyCloud" Storage Processing mode (launched from the context menu at the root of the file system, the storage can be found by the presence of the root/restsdk/data/files/ directory and the root/restsdk/data/db/index file.db) |
ENHANCED | the mode of exporting a list of files to csv |
ADDED | a shift option – to the Map Modification Mode |
ADDED | the support of Kuznyechik and Camellia encryption algorithms in TrueCrypt/VeraCrypt |
ADDED | the new error-processing scenario in the Data Extractor |
ENHANCED | the speed of calculating hash amounts for the map |
ADDED | SHA256 calculation |
ENHANCED | exporting to the forensic format |
NTFS file system
ENHANCED | operation of the "MFT Scanning" mode |
BtrFS file system
ADDED | support for checksums XXHASH, SHA256, BLAKE2b |
ADDED | support for the ZSTD compression algorithm |
ADDED | support for RAID profiles 1c3 and 1c4 |
ADDED | an experimental mode for searching metadata (with subsequent analysis) by arbitrary map in the disk address space, as well as by map of space allocated for metadata in the BtrFS address space |
Data Extractor RAID Edition
ENHANCED | building a map of RAID members can be run in the background |
ENHANCED | RAID integrity check can be run in the background |
ENHANCED | form opening for creating a new RAID |
PC-3000 SSD
Phison SSD
PS3110 controller:
ENHANCED | translator building algorithm |
ADDED | new loaders for PS3110 |
PS3111 Controller:
ADDED | support for B37R chips |
ADDED | new loaders |
ENHANCED | translator building algorithm |
Crucial/Micron Marvell SSD
ADDED | the ability to view/edit the dump of the SPI Flash chip |
Intel Postville
ENHANCED | after execution of the translator build, the reading of the logical image is automatically switched to reading using the translation tables |
Phison SSD
SM2258XT and SM2259XT controllers:
ADDED | new loaders |
ENHANCED | translator building algorithm |
PC-3000 SSD Extended
Phison SSD
ADDED | support for PS5013 PCIe NVMe controller
Supported drives: Smartbuy E13T, Apacer PP3480, Dexp L3, Novation 3D (PS5013) |
PS3110 controller:
ENHANCED | translator building algorithm |
ADDED | new loaders for PS3110 |
PS3111 controller:
ADDED | support for B37R chips |
ADDED | new loaders |
ENHANCED | translator building algorithm |
Lenovo Marvell NVMe SSD
ADDED | Lenovo Marvell NVMe and Ramaxel Marvell NVMe utilities
Ramaxel/Lenovo drives are supported:
Utility features:
|
Crucial/Micron Marvell SSD
ADDED | the ability to view/edit the dump of the SPI Flash chip |
Plextor Marvell SSD
ADDED | loading of the service firmware via the NVMe interface for Plextor M9Pe drives – in the master of transferring the drive to the Extended mode |
ADDED | ability to edit SPI Flash chip dump |
Intel Postville
ADDED | after execution of the translator build, the reading of the logical image is automatically switched to reading using the translation tables |
Silicon Motion SSD
SM2258XT and SM2259XT controllers:
ADDED | new loaders |
ENHANCED | translator building algorithm |
SM2263XT controller:
ENHANCED | translator building algorithm |
Contact us to learn more on how to become an authorized technical support user and receive the recent PC-3000 Software Updates: